10

Inorganic Phosphorus, mg/l

Inorganic Phosphorus, mg/l

a high temperature in an oxygen-starved atmosphere. This char has the characteristics of an enormous surface area per granule of carbon—100 acres or more per lb. This large surface area is a result of each particle containing an intricate network of inner channels and accounts for the carbon's great adsorptive capacity.

The treatment uses granular carbon in the form of a bed. Wastewater flows through this bed much like a sand filter. Organic molecules are attracted by the carbon and adsorbed on its surface. When the carbon becomes loaded with the adsorbed molecules and loses its adsorptive ability, it can be removed from the system and regenerated.

Figure 7.31.6 shows a PCT flow sheet. This figure shows all waste flow routes together with the backwash lines and the regeneration equipment shown in Figure 7.31.7. This treatment has great flexibility with interconnected carbon columns because any number of columns can be used in series while others are being refilled with fresh carbon.

In evaluating some processes, the EPA reports that the products of these processes (including carbon treatment) equal or exceed that of a well-operated conventional biological plant. The flow sheets in Figures 7.31.6 and 7.31.7 show major unit processes in PCT systems. Following pre-treatment, which includes screening and grit removal, these systems add and mix a coagulant such as lime. Recalcifying the sludge in a furnace can supply part of the lime coagulant dosage needed. The supernatant from the clarifier passes through a multimedia filter of sand and anthracite coal to remove the remaining SS, which is an inexpensive way to protect the carbon from solids carryover. The activated-carbon beds remove refractory colloidal and some soluble organic molecules.

After disinfection with chlorine, the treated effluent can be discharged. The removal efficiencies of this type of plant are 95 to 99% of organic material and 85 to 99% of phosphorus. The costs are significantly higher if a coagulant other than lime is used since lime can be recovered on site.

DIY Battery Repair

DIY Battery Repair

You can now recondition your old batteries at home and bring them back to 100 percent of their working condition. This guide will enable you to revive All NiCd batteries regardless of brand and battery volt. It will give you the required information on how to re-energize and revive your NiCd batteries through the RVD process, charging method and charging guidelines.