Table A28

Emission Factors for CO and Carbon Dioxide (CO2) from Uncontrolled Anthracite Coal Combustorsa

Source Category CO CO2

Emission Emission Emission Emission

Factor Factor Factor Factor

(lb/ton) Rating (lb/ton) Rating

Stoker-fired boilers 0.6 B 5680 C

FBC boilersb 0.6 E ND NA

aData from EPA, Compilation of Air Pollutant Emission Factors, AP-42, Fifth ed., U.S. Environmental Protection Agency, U.S. Government Printing Office, Washington, D.C., January 1995. Tons are short tons. Units are pounds of pollutant per ton of coal burned. To convert from lb/ton to kg/Mg, multiply by 0.5. ND, no data; NA, not applicable.

bFluidized-bed combustion (FBC) boilers burning culm fuel; all other sources burning anthracite coal.