Fire fighting equipment

Portable extinguishers

There are four principal types of portable extinguisher usually found on board ship. These are the soda-acid, foam, dry powder and carbon dioxide extinguishers.

Soda-acid extinguisher

The container of this extinguisher holds a sodium bicarbonate solution. The screw-on cap contains a plunger mechanism covered by a safety guard. Below the plunger is a glass phial containing sulphuric acid (Figure 13.4). When the plunger is struck the glass phial is broken and the acid and sodium bicarbonate mix. The resulting chemical reaction produces carbon dioxide gas which pressurises the space above the liquid forcing it out through the internal pipe to the nozzle. This extinguisher is used for Class A fires and will be found in accommodation areas.

Foam extinguisher—chemical

The main container is filled with sodium bicarbonate solution and a long inner polythene container is filled with aluminium sulphate (Figure 13.5(a)). The inner container is sealed by a cap held in place by a plunger. When the plunger is unlocked by turning it, the cap is released.

Water Extinguisher Diagram

The extinguisher is then inverted for the two liquids to mix. Carbon dioxide is produced by the reaction which pressurises the container and forces out the foam.

Foam extinguisher—mechanical

The outer container in this case is filled with water. The central container holds a carbon dioxide charge and a foam solution (Figure 13.5(b)). A plunger mechanism with a safety guard is located above the central container. When the plunger is depressed the carbon dioxide is released and the foam solution and water mix. They are then forced out through a special nozzle which creates the mechanical foam. This extinguisher has an internal pipe and is operated upright.

Foam extinguishers are used on Class B fires and will be located in the vicinity of flammable liquids.

Water Fire Extinguisher Mechanism
Figure 13.5(a) Foam fire extinguishers-—chemical foam

Strike knob

Safety guard

Piercer

Strike knob

Piercer

Spray outlet

Flammable Liquid Fire Foam

Figure 13.5(b) Foam fire extinguishers- mechanical foam

Spray outlet

Figure 13.5(b) Foam fire extinguishers- mechanical foam

Carbon dioxide extinguisher

A very strong container is used to store liquid carbon dioxide under pressure (Figure 13.6). A central tube provides the outlet passage for the carbon dioxide which is released either by a plunger bursting a disc or a valve operated by a trigger. The liquid changes to a gas as it leaves the extinguisher and passes through a swivel pipe or hose to a discharge horn.

Carbon dioxide extinguishers are mainly used on Class B and C fires and will be found in the machinery space, particularly near electrical

Class Confined Space
Figure 13.6 Carbon dioxide extinguisher

equipment. The carbon dioxide extinguisher is not permitted in the accommodation since, in a confined space, it could bekthal.

Dry powder extinguishers

The outer container contains sodium bicarbonate powder. A capsule of carbon dioxide gas is located beneath a plunger mechanism in the central cap (Figure 13.7). On depressing the plunger the carbon dioxide gas forces the powder up a discharge tube and out of the discharge nozzle.

The dry powder extinguisher can be used on all classes of fire but it has no cooling effect. It is usually located near electrical equipment in the machinery space and elsewhere on the ship.

Maintenance and testing

All portable extinguishers are pressure vessels and must therefore be regularly checked.

The soda-acid and foam extinguisher containers are initially tested to 25 bar for five minutes and thereafter at four-yearly intervals to 20 bar.

Carbon dioxide injector tube internal tube

Carbon dioxide injector tube internal tube

Marine Engineering Handbook

Plunger mechanism

Phial of carbon dioxide Hose

Safety cup

Plunger mechanism

Phial of carbon dioxide Hose

Safety cup

Outer container

Figure 1S.7 Dry powder extinguisher

The carbon dioxide extinguisher is tested to 207 bar initially every 10 years and after two such tests, every five years. The dry powder extinguisher is tested to 35 bar once every four years.

Most extinguishers should be tested by discharge over a period of one to five years, depending on the extinguisher type, e.g. soda-acid and dry powder types 20% discharged per year, foam types 50% discharged per year. Carbon dioxide extinguishers should be weighed every six months to check for leakage.

Where practicable the operating mechanisms of portable extinguishers should be examined every three months.

Any plunger should be checked for free movement, vent holes should be clear and cap threads lightly greased. Most extinguishers with screw-on caps have a number of holes in the threaded region. These are provided to release pressure before the cap is taken off: they should be checked to be clear.

Fixed installations

A variety of different fixed fire fighting installations exist, some of which are specifically designed for certain types of ship. A selection of the more general installations will now be outlined.

A sea water supply system to fire hydrants is fitted to every ship (Figure 13.8). Several pumps in the engine room will be arranged to supply the system, their number and capacity being dictated by legislation (Department of Transport for UK registered vessels). An emergency fire pump will also be located remote from the machinery space and with independent means of power.

Fire main

Accommodation deck hydrants

Isolating

Forecastle deck hydrant

Accommodation deck hydrants

Isolating

Forecastle deck hydrant roA

Hydraulic pump

Sea water suction

Sea water suction

Figure 18.8 Fire main roA

Hydraulic pump

Poop deck hydrant

Sea water suction

Sea water suction

Figure 18.8 Fire main

A system of hydrant outlets, each with an isolating valve, is located around the ship, and hoses with appropriate snap-in connectors are strategically located together with nozzles. These nozzles are usually of the jet/spray type providing either type of discharge as required. All the working areas of the ship are thus covered, and a constant supply of sea water can be brought to bear at any point to fight a fire.

While sea water is best used as a cooling agent in fighting Class A fires it is possible, if all else fails, to use it to fight Class B fires. The jet/spray nozzle would be adjusted to provide a fine water spray which could be played over the fire to cool it without spreading.

An international shore connection is always carried on board ship. This is a standard size flange which is fitted with a coupling suitable for the ship's hoses. The flange is slotted in order to fit any shore-side fire main and enable water to be brought on board a ship lying alongside.

Automatic water spray

The automatic spray or sprinker system provides a network of sprinkler heads throughout the protected spaces. This system may be used in accommodation areas, and in machinery spaces with certain variations in the equipment used and the method of operation.

The accommodation areas are fitted with sprinkler heads which both detect and extinguish fires. The sprinkler head is closed by a quartzoid bulb which contains a liquid that expands considerably on heating (Figure 13.9). When excessively heated the liquid expands, shatters the bulb and water will issue from the sprinkler head. A deflector plate on the sprinkler head causes the water to spray out over a large area.

The water is supplied initially from a tank pressurised by compressed air (Figure 13.10(a)). Once the tank pressure falls, as a sprinkler issues water, a salt water pump cuts in automatically to maintain the water supply as long as is necessary. The system is initially charged with fresh water to reduce corrosion effects.

Valve and gasket

Valve and gasket

Figure 15.9 Sprinkler head

Spray deflector

Spray deflector

Figure 15.9 Sprinkler head

Accommodation '-Machinery (b) Sprayer system

Figure 13.10 Automatic water spray systems, (a) sprinkler system; (b) sprayer system

Accommodation '-Machinery (b) Sprayer system

Figure 13.10 Automatic water spray systems, (a) sprinkler system; (b) sprayer system

The complete installation is divided into several sections, each containing about 150 to 200 sprinklers and having an alarm valve. When one or more sprinklers operate water flows through the section valve and sounds an alarm and also provides a visual display identifying the section containing the fire.

In the machinery space the sprinkler heads are known as 'sprayers' and have no quartzoid bulb. Also the section valves are manually operated to supply water to the sprayers (Figure 13.10(b)). The system is pressurised by compressed air with a salt water pump arranged to cut in automatically if the pressure drops. The accommodation and machinery space systems may be combined by a valve which is normally kept locked shut.

The system should be regularly checked by creating fault conditions at the various section control valves by opening a test valve, and checking for audible and visual alarms.

Water mist (fog)

Water mist (fog) sprinklers are being used as an alternative to, the now banned, Halon fire suppression systems. The mist system delivers very small water particles, which are able to remain suspended in the air. The water particles are evaporated by the heat of the fire and the expanding vapour displaces oxygen. The combined cooling and oxygen starvation effects quickly extinguishes a fire. Less water is used than with sprinkler systems and the mist has proved effective against liquid fuel fires, making it suitable for use in machinery spaces.

Research is continuing, in particular as to the effectiveness of mist in a large machinery space. Water mist is accepted as a fire extinguishing agent, with respect to SOLAS fire protection requirements.

Foam systems

Foam spreading systems are designed to suit the particular ship's requirements with regard to quantity of foam, areas to be protected, etc. Mechanical foam is the usual substance used, being produced by mixing foam making liquid with large quantities of water. Violent agitation of the mixture in air creates air bubbles in the foam.

An automatic foam induction system is shown in Figure 13.11. The automatic inductor unit ensures the correct mixing of water and foam compound which is then pumped as the foam making solution to the hydrants for use. The foam compound tank is sealed to protect the contents from deterioration and has linked compound supply and air vent valves. To operate the system these two linked valves are opened and the fire pump started. Foam mixing is carefully metered by the automatic inductor unit. The fire pump and compound tank must be located outside the protected space.

High-expansion foam systems are also available where a foam generator produces, from foam concentrate and sea water, a thousand

Figure IS. 11 Foam induction system

times the quantity of foam. The generator blows air through a net sprayed with foam concentrate and water. The vasdy expanded foam is then ducted away to the space to be protected. The foam is an insulator and an absorber of radiant heat; it also excludes oxygen from the fire

Carbon dioxide flooding

A carbon dioxide flooding system is used to displace the oxygen in the protected space and thus extinguish the fire. The carbon dioxide is stored as a liquid under pressure in cylinders.

The volume of space to be protected determines the number of cylinders required. A common battery of cylinders may be used to protect both cargo holds and machinery space.

The cargo space system is normally arranged for smoke detection, alarm and carbon dioxide flooding (Figure 13.12).

Small air sampling pipes from the individual cargo holds are led into a cabinet on the bridge. Air is drawn from each hold by a small fan and each pipe is identified for its particular hold. If smoke is drawn into the cabinet from one of the holds it will set off an alarm. The smoke is also passed into the wheelhouse where it can be detected by personnel on watch.

The location of the fire can be identified in the cabinet and the hold distribution valve below the cabinet is operated. This valve shuts off the sampling pipe from the cabinet and opens it to the carbon dioxide main leading from the cylinder battery. A chart will indicate the number of

CO, room

Fan motor box Diverting valve

Wheelhouse top

Smoke detection cabinet in wheelhouse

CO, room

Fan motor box Diverting valve

Wheelhouse top

Smoke detection cabinet in wheelhouse

Carbon Dioxide Flooding System
Figure 13.12 Carbon dioxide detection and flooding system

cylinders of gas to be released into the space and this is done by a hand operated lever.

The machinery space system is designed to quickly discharge the complete battery of cylinders. Before the gas is released the space must be clear of personnel and sealed against entry or exhausting of air.

The discharge valve is located in a locked cabinet, with the key in a glass case nearby. Opening the cabinet sounds an alarm to warn personnel of the imminent discharge of the gas. The discharge valve is opened and an operating lever pulled.

The operating lever opens two gas bottles which pressurise a gang release cylinder that, in turn, moves an operating cable to open all the bottles in the battery. The carbon dioxide gas then quickly floods the machinery space, filling it to 30% of its volume in two minutes or less.

The air sampling system can be checked when the holds are empty by using a smoking rag beneath a sampling point. Flow indicators, usually small propellers, are fitted at the outlet points of the smoke detecting pipes as a visual check and an assurance that the pipes are clear. To check for leakage the gas cylinders can be weighed or have their liquid levels measured by a special unit.

Inert gas

Inert gases are those which do not support combustion and are largely nitrogen and carbon dioxide. Large quantities suitable for fire extinguishing can be obtained by burning fuel in carefully measured amounts or by cleaning the exhaust gases from a boiler.

Oil filter-pilot burner

Oil filter-pilot burner

Marine Engineering Handbook
Figure 13.13 Inert gas generator

/next gas generator

The inert, gas generator (Figure 13.13) burns fuel in designed quantities to produce perfect combustion. This provides an exhaust gas which is largely nitrogen and carbon dioxide with a very small oxygen content. The exhaust gases pass to a cooling and washing chamber to remove sulphur and excess carbon. The washed or scrubbed exhaust gas is now inert and passes to a distribution system for fire extinguishing. The complete unit is arranged to be independently operated in order to supply inert gas for as long as the fuel supply lasts.

Funnel gas inertmg

A system much used on tankers where boiler exhaust gases are cleaned and inerted is shown in Figure 13.14. The exhaust gas is cleaned in a scrubbing tower, dried and filtered before being passed to the deck mains for distribution. The gas will contain less than 5% oxygen and is therefore considered inert. It is distributed along the deck pipes by fans and passes into the various cargo tanks. Seals in the system act as non-return valves to prevent a reverse flow of gas.

The inert gas is used to blanket the oil cargo during discharging operations. Empty tanks are filled with gas and the inert gas is blown out when oil is loaded.

Inert gas-producing units have the advantage of being able to continuously produce inert gas. A bottle storage system, such as carbon dioxide flooding, is a 'one-shot:' fire extinguisher which leaves a ship unprotected until further gas supplies can be obtained.

Halon system

Halon 1301 (BTM) and Halon 1211 (BCF) are two halogenated hydrocarbon gases with special fire extinguishing properties. Unlike other extinguishing agents which cool the fire or displace oxygen the Halon gases inhibit the actual flame reaction. As a result of its low vapour pressure when liquefied Halon can be stored in low-pressure containers. Alternatively if a standard carbon dioxide cylinder is used then approximately three times as much gas can be stored. An additional advantage is that the atmosphere in a Halon flooded space is not toxic, although some highly irritant gases are produced in the extinguishing process.

A Halon storage system would be very similar to one using carbon dioxide except that fewer cylinders would be required. The liquefied Halon is usually pressurised in the cylinders with nitrogen in order to increase the speed of discharge. Bulk storage tanks of Halon gas are also used with cylinders of carbon dioxide and compressed air being used to operate the control system and expel the gas.

Fresh air intet

Scrubber

Boiler uptake

Fresh air intet

Scrubber

Boiler uptake

Naval Engineer Imaages

Drain overboard

Figure 13.14 Funnel gas inerting system

Drain overboard

Figure 13.14 Funnel gas inerting system

Iialons, while being excellent fire extinguishing gases, have a greater ozone depleting potential than CFCs. IMO has adopted amendments to the SOLAS Convention banning any new installations of halon systems on ships, which are now in force. IMO is further urging annual leakage inspections for existing installations and actively considering the phasing-out of all existing systems in the near future.