Info

Anode

H 2 :80% CO 2 :20%

Cathode

Air

Table 2. Experimental Conditons

Na

Variable Item

Constant Item

100. 150, 200, 250, 300 (mA/cm 2)

Air Utilization = 60% Fuel Utilization = 80%

©

Air Utilization 50, 60, 70 (%)

Current Density = 300 mA/cm 2 Fuel Utilization = 80%

©

Fuel Utilization 50, 60, 70, 80, 90 (%)

Current Density = 300 mA/cm 2 Air Utilization = 60%

The subject part for measurement is 3P (13C~ 18C) shown in Figurel, and fit up twenty-five thermocouples on a cell shown in Figure2 respectivery.