Plating in High Efficiency Sodium and Potassium Cyanide Baths

High-efficiency sodium and potassium cyanide baths allow the use of higher current densities. Cyanide plating baths typically decrease in cathode efficiency, or speed of deposition, with increasing current, which accounts for the good plate distribution (throwing power). The cathode efficiency approaches 100% only at low current densities, often 10A/dm2 or less. With more practical current densities of 2.0 to 3.0 A/dm2, the cathode efficiency may drop 20%, especially with lower agitation rates. The sodium or potassium constituent improves the conductivity of the bath.

Operation of the sodium cyanide and potassium cyanide electrolytes at 66 to 74 °C (150 to 165 °F) produces quality deposits. Temperatures in excess of 74 °C (165 °F) allow the use of higher current densities, but breakdown of the cyanide becomes excessive at elevated temperatures. The anode current densities are limited by polarization, resulting in poor anode efficiency and higher voltage requirements. The cathode current densities are limited by burning of the deposit, resulting in reduced efficiency, loss of brightness, and roughness. These limits are higher in the potassium cyanide electrolyte.

Agitation of sodium cyanide and potassium cyanide high-efficiency baths is important for achieving maximum plating speed. Agitation can be accomplished by solution movement, cathode-rod movement, or use of air. Each type of agitation improves the maximum allowable current densities, with air agitation providing the greatest improvement. However, it should be noted that carbonate levels in air-agitated baths tend to increase at a greater rate than baths using mechanical agitation. All three types of agitation may be used within a single bath. Solution movement can be accomplished by mixing or by the flow of solution through filtration equipment. Cathode-rod movement of about 1 to 2 m/min (3 to 7 ft/min) allows increased plating rates. Gentle air agitation should be supplied by the use of a low-pressure blower that has a clean, filtered air source. Care must be taken to use clean, oil-free air for agitation to avoid contamination of the plating solution.

Filtration is also essential when operating high-efficiency cyanide copper electrolytes, especially for plating deposits thicker than 13 pm (0.5 mil). Filtration equipment should have the capability of one to two complete turnovers of the solution each hour while removing particulate matter from the electrolyte. Roughness of the copper deposits from particulate matter is often caused by faulty cleaning or by the formation of metallic copper or cuprous oxide particles at the anodes. Suspended dirt or solid matter in the cyanide copper electrolyte also causes surface roughness. Anode bags of proper size, material, weight, and weave are beneficial in retaining particulate matter formed at the anode. Other foreign particles introduced into the cyanide copper electrolyte are removed by the filtration equipment.

Carbonate buildup in high-efficiency copper cyanide baths can adversely affect the bath operation. High concentrations of carbonate reduce plating efficiency and speed. Excessive carbonates also affect the smoothness of the deposits. Carbonate contents of 120 to 150 g/L (16 to 20 oz/gal) or more may result in lower plating efficiency and plating speed. Excessive carbonates can also lower and reduce the acceptable plating range. These effects are more pronounced in a sodium cyanide bath than in a potassium cyanide bath.

The primary source of carbonate formation is the breakdown of cyanide as a result of poor anode efficiency. Operating cyanide electrolytes at temperatures above the recommended levels can also result in carbonate formation. Operating temperatures above about 74 °C (165 °F) cause decomposition of the cyanide ion. Air containing high levels of carbon dioxide should not be used in air-agitated systems, because the carbon dioxide is dissolved by the alkaline plating solution, also forming carbonate. The air source for air-agitated systems should be placed where it provides a clean, fresh supply.

Excessive carbonates can be removed by freezing or precipitation with lime or proprietary additives. Sodium cyanide baths can be treated either by precipitation or freezing. Potassium cyanide baths can only be treated by precipitation. Freezing is not effective for potassium cyanide baths because of the high solubility of the carbonate salts.

Current interruption cycles frequently improve the operating range of high-efficiency sodium or potassium copper cyanide plating solutions. Current interruption cycles generally allow the use of higher current densities while maintaining bath efficiency. Current interruption cycles also improve the brightness of the copper deposits, and in some cases they give excellent deposit brightness from bright plating baths that are so contaminated that acceptable deposits cannot be produced when using continuous direct current.

Current interruption cycles in the range of 8 to 15 s plating time followed by 1 to 3 s current interruption are generally used. Plating times of less than 8 s and current interruptions of more than 3 s lower the net plating rate. Plating times of more than 15 s and current interruption of less than 1 s reduce the benefits obtained by using a current interruption cycle.

The use of periodic current reversal can also be used to great advantage in high-efficiency copper cyanide plating solutions. This technique involves plating parts in the conventional manner for a selected time and then deplating for a shorter period by reversing the current. Shorter periodic reversal cycles, such as 2 to 40 s of plating followed by 1 to 10 s of deplating (reversal), result in improved deposit brightness similar to that obtained with current interruption. A major advantage in using periodic reversal is the degree of leveling that can be achieved, particularly when relatively long reversal cycles are used. These longer cycles, in excess of 45 s direct with reverse cycles in excess of 10 s, can provide leveling characteristics in excess of 50%. The use of periodic reversal permits the use of higher plating and deplating current densities.

The leveling characteristics of the deposit are improved by increasing the reversal current, whereas cycle efficiency is increased by lowering the reversal current. Figure 3 shows cycle efficiency for periodic-reverse plating. Figure 4 indicates thickness of deposit as a function of cycle efficiency.

Fig. 3 Cycle efficiency during copper plating with periodic current reversal. Source: Ref 9

Thickness, m-il/min 0.02 0.04 0.06 0.03 0.10 0.12 0.14

Thickness, m-il/min 0.02 0.04 0.06 0.03 0.10 0.12 0.14

Thickness, ^m/min

Fig. 4 Thickness of copper deposits as a function of cycle efficiency and current density during plating with periodic current reversal. Source: Ref 9

Another current-interrupting scheme being used for this and other copper plating systems is pulse plating. This normally involves a pulse power source (rectifier) that produces square-wave current pulses. Square wave conventionally suggests a pulse with a rise-and-fall time of approximately 10 to 85 ps and a standard frequency of 150 and 10,000 cycles. The periodic interruption of the current with proper time sequences allows much faster plating without surface burning, produces finer grain deposits, and increases throwing power and distribution.

Proprietary additives are used in high-efficiency copper cyanide baths to improve anode corrosion, increase both anode and cathode efficiencies, and control contamination. Organic and metallic additives are also used to improve deposit characteristics and brightness. These additives produce deposits ranging from matte to full-bright.