2 X 3217

Drrit 0 73

In SI units Z2 = ZS — 1.219 + -p = 9.95 — 1.219 + = 9.1 m

2.42

If the system is not externally primed, the centrifugal pump selected must be able to deliver at least 28,000 gpm (6400 m3/h) at 38.68 ft (11.79 m) total head and must be provided with a driver having adequate power for this condition. After the system is primed, the pump must be capable of delivering at least 70,000 gpm (15,900 m3/h) at 13.17 ft (4.01 m) (see Figure 28).